The Firefree Wildfire System is a high-performance fire coating system, and only system fully tested to
the ASTM E2768-30 for fire ignition resistance (ASTM E84 30 Minute Extended), and the ASTM D2898 method B for weatherization.
In order to meet the WUI standards, any system is required to pass BOTH fire and weatherization testing to show that the fire resistant properties will survive long term exposure. Assuming that a fire resistant coating product designed for interior use can be covered or top coated by any method or product will not work, as the combination of products might affect both the fire and weather properties.
The Firefree System has been tested first to severe weatherization exposure, following by severe fire testing of the weatherized panels showing that the product retained its fire ignition resistance after long term weather exposure. The Firefree Wildfire System received listing reports ESR-1205 and ESR1206 from ICC Evaluation Service (ICC-ES), for both ASTM E2768-11 for ignition resistance (ASTM E84 30 Minutes Extended) and ASTM D2898-10 for weatherization.
All testing has been validated through ICC/IAS certified, independent third-party testing laboratories, including:
Independent ICC/IAS, 3rd party verification of the coating system application
Independent ICC/IAS, 3rd party weatherization testing (Western Fire Center)
Independent ICC/IAS, 3rd party testing of 3 sets of weatherized panels (QAI).
Three continuous sets of weatherized panels must pass. If one set fails, the entire process, including weatherization, must be repeated. The Firefree System met and passed all three sets.
The Firefree Wildfire System has also been tested to comply with California Building Code (CBC), SFM 12-7A-3 conditions in accordance with ASTM E 2957 for fire resistance to wildfire flame penetration of eaves, soffits and ignition-resistant materials to other assembly projections including (deck structures, cantilevers…).
FfA needs to be applied first, with a required thickness of two coats (2) @ 10 mils dry each, for a total applied thickness of 20 mils dry. The net coverage with the specified two coats is 53sqft/gal (1.30M2/L). FfA then needs to be top coated with FfE, as follows.
FfE then needs to be applied over FfA, with a required thickness of two coats (2) @ 3 mils dry each, for a total applied thickness of 6 mils dry. The net coverage with the specified two coats is 110 sqft/gal (2.70M2/L).
In addition to protecting FfA, FfE will provide both an exterior stain-resistant prime and a durable white, satin finish. If a different color or finish is desired, FfE can top coated with most premium paints to achieve the desired color and finish. For large orders (>200 gallons) FfE can be tinted by Firefree Coatings. Please contact Firefree for such custom tinted orders.